Your browser doesn't support javascript.
Show: 20 | 50 | 100
Results 1 - 5 de 5
Filter
1.
Lancet Reg Health Eur ; 21: 100479, 2022 Oct.
Article in English | MEDLINE | ID: covidwho-1977613

ABSTRACT

Background: Introduction of the Omicron variant caused a steep rise in SARS-CoV-2 infections despite high vaccination coverage in the Danish population. We used blood donor serosurveillance to estimate the percentage of recently infected residents in the similarly aged background population with no known comorbidity. Methods: To detect SARS-CoV-2 antibodies induced due to recent infection, and not vaccination, we assessed anti-nucleocapsid (anti-N) immunoglobulin G (IgG) in blood donor samples. Individual level data on SARS-CoV-2 RT-PCR results and vaccination status were available. Anti-N IgG was measured fortnightly from January 18 to April 3, 2022. Samples from November 2021 were analysed to assess seroprevalence before introduction of the Omicron variant in Denmark. Findings: A total of 43 088 donations from 35 309 Danish blood donors aged 17-72 years were screened. In November 2021, 1·2% (103/8 701) of donors had detectable anti-N IgG antibodies. Adjusting for test sensitivity (estimates ranging from 74%-81%) and November seroprevalence, we estimate that 66% (95% confidence intervals (CI): 63%-70%) of the healthy, similarly aged Danish population had been infected between November 1, 2021, and March 15, 2022. One third of infections were not captured by SARS-CoV-2 RT-PCR testing. The infection fatality rate (IFR) was 6·2 (CI: 5·1-7·5) per 100 000 infections. Interpretation: Screening for anti-N IgG and linkage to national registers allowed us to detect recent infections and accurately assess assay sensitivity in vaccinated or previously infected individuals during the Omicron outbreak. The IFR was lower than during previous waves. Funding: The Danish Ministry of Health.

2.
Int J Infect Dis ; 116: 289-292, 2022 Mar.
Article in English | MEDLINE | ID: covidwho-1633307

ABSTRACT

OBJECTIVES: To evaluate long-term sensitivity for detection of total antibodies against SARS-CoV-2 METHODS: From week 41, 2020, through week 26, 2021, all Danish blood donations were tested for SARS-CoV-2 antibodies with the Wantai assay. The results were linked with polymerase chain reaction (PCR) test results from the Danish Microbiological Database (MiBa). RESULTS: During the study period, 105,646 non-vaccinated Danish blood donors were tested for SARS-CoV-2 antibodies, and 3,806 (3.6%) had a positive PCR test before the blood donation. Among the donors with a positive PCR test, 94.2% subsequently also had a positive antibody test. The time between the positive PCR test and the antibody test was up to 15 months and there was no evidence of a decline in proportion with detectable antibodies over time. A negative serological result test was associated with a higher incidence of re-infection (Incidence Rate Ratio = 0.102 (95% confidence interval (CI): 0.039-0.262)). CONCLUSION: Among healthy blood donors, 94.2% developed SARS-CoV-2 antibodies after infection, and a lack of detectable antibodies was associated with re-infection.


Subject(s)
COVID-19 , SARS-CoV-2 , Antibodies, Viral , COVID-19/diagnosis , Humans , Reinfection , Seroepidemiologic Studies , Serologic Tests
3.
J Infect Dis ; 225(2): 219-228, 2022 01 18.
Article in English | MEDLINE | ID: covidwho-1522221

ABSTRACT

BACKGROUND: Studies presenting severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) infection fatality rate (IFR) for healthy individuals are warranted. We estimate IFR by age and comorbidity status using data from a large serosurvey among Danish blood donors and nationwide data on coronavirus disease 2019 (COVID-19) mortality. METHODS: Danish blood donors aged 17-69 years donating blood October 2020-February 2021 were tested with a commercial SARS-CoV-2 total antibody assay. IFR was estimated for weeks 11 to 42, 2020 and week 43, 2020 to week 6, 2021, representing the first 2 waves of COVID-19 epidemic in Denmark. RESULTS: In total, 84944 blood donors were tested for antibodies. The seroprevalence was 2% in October 2020 and 7% in February 2021. Among 3898039 Danish residents aged 17-69 years, 249 deaths were recorded. The IFR was low for people <51 years without comorbidity during the 2 waves (combined IFR=3.36 per 100000 infections). The IFR was below 3‰ for people aged 61-69 years without comorbidity. IFR increased with age and comorbidity but declined from the first to second wave. CONCLUSIONS: In this nationwide study, the IFR was very low among people <51 years without comorbidity.


Subject(s)
Antibodies, Viral/blood , Blood Donors , COVID-19/diagnosis , SARS-CoV-2/isolation & purification , Adolescent , Adult , Aged , COVID-19/blood , COVID-19/epidemiology , Comorbidity , Denmark/epidemiology , Female , Humans , Male , Middle Aged , Seroepidemiologic Studies , Young Adult
4.
Int J Infect Dis ; 103: 381-388, 2021 Feb.
Article in English | MEDLINE | ID: covidwho-968465

ABSTRACT

OBJECTIVES: Evaluate six commercial serological assays for detection of IgA, IgM or IgG SARS-CoV-2 antibodies in different disease severities. METHODS: Three lateral flow tests (LFTs) (Acro IgM/IgG, CTK IgM/IgG, Livzon IgM/IgG) and three ELISA assays (Euroimmun IgA and IgG, Wantai IgM) were included. Application was evaluated using samples from 57 patients with a positive SARS-CoV-2 reverse transcription polymerase chain reaction, stratified according to disease severity. Specificity was assessed using historical samples from 200 blood donors. RESULTS: While IgM LFTs failed to detect SARS-CoV-2 antibodies in 37-84% of non-hospitalised patients, the Wantai IgM ELISA detected antibodies in 79%. The Euroimmun IgG ELISA detected antibodies in 95% of non-hospitalised patients. IgA, IgM and IgG ELISA levels were initially low, increased over time, and correlated with disease severity. LFT sensitivity declined in samples taken >28 days after symptom onset/resolution. The Livzon IgG LFT had the highest specificity (98.5%), followed by the Euroimmun IgG ELISA (96.2%). The specificity for Euroimmun IgA ELISA improved (≥97.5%) using a custom cut-off value (4.0). CONCLUSIONS: The sensitive and semi-quantitative ELISA assays are most appropriate for serologic detection of SARS-CoV-2 infection in mild cases. Livzon LFT and Euroimmun ELISA had the highest specificity among the IgG assays, making them most suitable for seroprevalence studies.


Subject(s)
Antibodies, Viral/blood , COVID-19 Serological Testing/methods , COVID-19/diagnosis , Adult , Enzyme-Linked Immunosorbent Assay , Female , Humans , Immunoglobulin G/blood , Immunoglobulin M/blood , Male , Middle Aged , SARS-CoV-2 , Sensitivity and Specificity
5.
Clin Infect Dis ; 72(2): 249-253, 2021 01 27.
Article in English | MEDLINE | ID: covidwho-614253

ABSTRACT

BACKGROUND: The pandemic due to severe acute respiratory syndrome coronavirus 2 (SARS-CoV-2) has tremendous consequences for our societies. Knowledge of the seroprevalence of SARS-CoV-2 is needed to accurately monitor the spread of the epidemic and to calculate the infection fatality rate (IFR). These measures may help the authorities make informed decisions and adjust the current societal interventions. The objective was to perform nationwide real-time seroprevalence surveying among blood donors as a tool to estimate previous SARS-CoV-2 infections and the population-based IFR. METHODS: Danish blood donors aged 17-69 years giving blood 6 April to 3 May were tested for SARS-CoV-2 immunoglobulin M and G antibodies using a commercial lateral flow test. Antibody status was compared between geographical areas, and an estimate of the IFR was calculated. Seroprevalence was adjusted for assay sensitivity and specificity taking the uncertainties of the test validation into account when reporting the 95% confidence intervals (CIs). RESULTS: The first 20 640 blood donors were tested, and a combined adjusted seroprevalence of 1.9% (95% CI, .8-2.3) was calculated. The seroprevalence differed across areas. Using available data on fatalities and population numbers, a combined IFR in patients <70 years is estimated at 89 per 100 000 (95% CI, 72-211) infections. CONCLUSIONS: The IFR was estimated to be slightly lower than previously reported from other countries not using seroprevalence data. The IFR is likely severalfold lower than the current estimate. We have initiated real-time nationwide anti-SARS-CoV-2 seroprevalence surveying of blood donations as a tool in monitoring the epidemic.


Subject(s)
Blood Donors , COVID-19 , Adolescent , Adult , Aged , Antibodies, Viral , Humans , Middle Aged , SARS-CoV-2 , Seroepidemiologic Studies , Young Adult
SELECTION OF CITATIONS
SEARCH DETAIL